Start with the simple things
Before assuming the worst, confirm the basics. Is the plug seated, is the socket live, and has the circuit breaker tripped? Is the thermostat set correctly, or has someone turned the dial to its warmest setting? Is the fridge in a mode such as holiday or demo that holds the compressor off?
These sound trivial, but a fair share of callouts end at one of them, and checking costs nothing.
Test the door seal
Close the door on a sheet of paper so half of it is inside the fridge and half outside. Pull it gently. If it slides out with almost no resistance, the seal is not gripping at that point. Repeat at the top, middle and bottom of the door, and along the hinge side.
A hardened or torn gasket lets warm, moist air in continuously. The fridge runs longer, frost builds up and the cabinet never quite reaches temperature. On the coast, seals also harden faster because of salt and sun exposure.
Look at airflow and dust
A fridge removes heat through its condenser, which is the grille on the back or the coil behind a plinth. If that surface is packed with dust, pet hair or salt dust, it cannot reject heat and the cabinet warms up.
Check that there is space around the unit, that nothing is pressed against the condenser, and that the internal fan is moving air rather than blocked by an overfilled shelf. In a frost-free fridge, an iced-up back panel usually points at the defrost system rather than at how full the fridge is.
Read the frost pattern
If you can see the evaporator, the frost pattern is informative. An even layer of frost across the whole coil suggests the sealed system is working. Frost on one small section only, or none at all while the compressor runs, suggests a refrigerant or restriction problem.
This is the point where DIY diagnosis should stop. The sealed system needs gauges, a leak detector and refrigerant handling, none of which belong in a home toolkit.
Listen
A faint hum with occasional clicks is normal. A clicking every minute or two with no start is often a start relay or capacitor. A compressor that is hot and silent, or a fan that is not turning, points at specific components. Note what you hear, because it shortens the diagnosis.
What not to do
Some common reactions make things worse:
- Do not chip ice off with a knife or screwdriver, because a punctured evaporator turns a cheap repair into a sealed-system job
- Do not keep switching the unit off and on to see if it recovers, which stresses the compressor
- Do not lay a fridge down to move it and stand it up immediately, since the oil needs time to settle before it runs
- Do not block the vents inside the cabinet to fit more in
- Do not add refrigerant yourself, and never use a top-up product that does not address the leak
What to tell the technician
Make, model and age of the unit. Whether the freezer section still works. The temperature it is actually reaching, if you have a thermometer. When the fault started and whether anything changed, such as a move, a power cut or a door left open. Whether it is holding food, and how much. That information usually decides whether the visit is a repair or a stock-rescue job.